Could not find component on update server. Contact VMware Support or your system administrator. VMware Tools for Windows 2000 or later: Could not find component on update server. Could not find component on update server. Contact VMware Support or your system administrator. Running Windows version 7.0 sp1 and Vmware player 7.1.1 build-2771112 When i try to update the player or install the tools for windows I get the error Could not find component on update server.
- Vmware Player Could Not Find Component On Update Server Windows 10
- Vmware Player Tools Could Not Find Component On Update Server
- Vmware Player Could Not Find Component On Update Server Settings
- Vmware Player 16 Could Not Find Component On Update Server
- Vmware Player Could Not Find Component On Update Server Settings
Update Manager enables centralized, automated patch and version management for VMware vSphere and offers support for VMware ESXi hosts, virtual machines, and virtual appliances.
With Update Manager, you can perform the following tasks:
- Upgrade and patch ESXi hosts.
- Install and update third-party software on hosts.
- Upgrade virtual machine hardware, VMware Tools, and virtual appliances.
Update Manager requires network connectivity with VMware vCenter Server. Each installation of Update Manager must be associated (registered) with a single vCenter Server instance.
The Update Manager module consists of a server component and of a client component.
Vmware Player Could Not Find Component On Update Server Windows 10
You can use Update Manager with either vCenter Server that runs on Windows or with the vCenter Server Appliance.
If you want to use Update Manager with vCenter Server, you have to perform Update Manager installation on a Windows machine. You can install the Update Manager server component either on the same Windows server where the vCenter Server is installed or on a separate machine. To install Update Manager, you must have Windows administrator credentials for the computer on which you install Update Manager.
If your vCenter Server system is connected to other vCenter Server systems by a common vCenter Single Sign-On domain, and you want to use Update Manager for each vCenter Server system, you must install and register Update Manager instances with each vCenter Server system. You can use an Update Manager instance only with the vCenter Server system with which it is registered.
The vCenter Server Appliance delivers Update Manager as an optional service. Update Manager is bundled in the vCenter Server Appliance.
In vSphere 6.5, it is no longer supported to register Update Manager to a vCenter Server Appliance during installation of the Update Manager server on a Windows machine.
The Update Manager client component is a plug-in that runs on the vSphere Web Client. The Update Manager client component is automatically enabled after installation of the Update Manager server component on Windows, and after deployment of the vCenter Server Appliance.
You can deploy Update Manager in a secured network without Internet access. In such a case, you can use the VMware vSphere Update Manager Download Service (UMDS) to download update metadata and update binaries.
VMware vSphere also affected by multiple vulnerabilities since its uses Intel/AMD platforms. VMware vSphere has multiple layers of virtualization and sadly, you should apply/update the patches for all the components which includes Operating systems, virtual machines, virtual appliances, hypervisors, server firmware, and CPU microcode. Operating system patches can reduce the risk with help of hypervisor patches without updating the server firmware (CPU microcode update) but it would be more secure if you update the hardware firmware as along with Hypervisor update and VM guest patching (Linux/Windows).
Here is the list of three discovered Meltdown and Spectre variants:
- Variant 1: bounds check bypass (CVE-2017-5753) – a.k.a. Spectre
- Variant 2: branch target injection (CVE-2017-5715) – a.k.a. Spectre
- Variant 3: rogue data cache load (CVE-2017-5754) – a.k.a. Meltdown
VMware classifies the mitigation in the below listed category.
- Hypervisor-Specific Mitigation
- Hypervisor-Assisted Guest Mitigation
- Operating System-Specific Mitigations
You must know about all the three different type mitigation before applying the patches since it could lead to performance issues.
Hypervisor-Specific Mitigation:
VMware Hypervisor is affected by Spectre – variant 1 & Variant 2. Meltdown doesn’t affect VMware vShpere hypervisor but guest require patches for both Spectre & Meltdown Vulnerabilities.
Hypervisor-Assisted Guest Mitigation
It virtualizes the new speculative-execution control mechanism for guest VMs so that a Guest OS can mitigate leakage between processes within the VM. This mitigation requires that specific microcode patches that provide the mechanism are already applied to a system’s processor(s) either by ESXi or by a firmware/BIOS update from the system vendor.
Operating System-Specific Mitigation:
Mitigation for Operating Systems are provided by respective OS Vendors. If you have virtual appliances, virtual appliance vendor will need to integrate these into their appliances and provide an updated appliance.
VMware Products which are affected by Spectre:
- VMware vSphere ESXi (ESXi)
- VMware Workstation Pro / Player (Workstation)
- VMware Fusion Pro / Fusion (Fusion)
- VMware vCenter Server (VC)
Hypervisor-Specific Mitigation:
VMware Product | Product Version | Apply Patch | Mitigation/ Workaround |
ESXi | 6.5 | ESXi650-201712101-SG | None |
ESXi | 6 | ESXi600-201711101-SG | None |
ESXi | 5.5 | ESXi550-201709101-SG* | None |
Workstation | 14 | Not Affected | None |
Workstation | 12 | 12.5.8 | None |
Fusion | 10x | Not Affected | None |
Fusion | 8x | 8.5.9 | None |
* This patch mitigates CVE-2017-5715 but not CVE-2017-5753.
Hypervisor-Assisted Guest Remediation:
(Not Recommended by VMware due to microcode issue. )
To remediate CVE-2017-5715 in the Guest OS, the following VMware and third-party requirements must be met:
VMware Requirements
- Deploy the updated version of vCenter Server listed in the table (if vCenter Server is used).
- Deploy the ESXi patches and/or the new versions for Workstation or Fusion listed in the table.
- Ensure that your VMs are using Hardware Version 9 or higher. For best performance, Hardware Version 11 or higher is recommended. VMware Knowledge Base article 1010675 discusses Hardware Versions.
Third party Requirements
- Deploy the Guest OS patches for CVE-2017-5715. These patches are to be obtained from your OS vendor.
- Update the CPU microcode. Additional microcode is needed for your CPU to be able to expose the new MSRs that are used by the patched Guest OS. This microcode should be available from your hardware platform vendor.
VMware is providing several versions of the required microcode from Intel and AMD through ESXi patches listed in the table. See VMware Knowledge Base 52085 for more details.
VMware Product | Product Version | Apply Patch | Mitigation/ Workaround |
vCenter | 6.5 | 6.5 U1e* | None |
vCenter | 6 | 6.0 U3d* | None |
vCenter | 5.5 | 5.5 U3g* | None |
ESXi | 6.5 | ESXi650-201801401-BGESXi650-201801402-BG** | None |
ESXi | 6 | ESXi600-201801401-BG ESXi600-201801402-BG** | None |
ESXi | 5.5 | ESXi550-201801401-BG** | None |
“Intel has notified VMware of recent sightings that may affect some of the initial microcode patches that provide the speculative execution control mechanism for a number of Intel Haswell and Broadwell processors. The issue can occur when the speculative execution control is actually used within a virtual machine by a patched OS. At this point, it has been recommended that VMware remove exposure of the speculative-execution mechanism to virtual machines on ESXi hosts using the affected Intel processors until Intel provides new microcode at a later date.”
Affected VMware Virtual Appliances : (VMware KB)
Vmware Player Tools Could Not Find Component On Update Server
- VMware Identity Manager (Workaround KB 52284)
- VMware vCenter Server 6.5 (Workaround KB 52312)
- VMware vCenter Server 6.0 (Workaround KB 52312)
- VMware vSphere Integrated Containers
- VMware vRealize Automation
Unaffected Virtual Appliances : (VMware KB)
Vmware Player Could Not Find Component On Update Server Settings
- vCloud Availability for vCloud Director
- VMware Horizon DaaS Platform
- VMware Integrated OpenStack
- VMware Mirage
- VMware NSX for vSphere
- VMware NSX-T
- VMware Skyline Appliance
- VMware Unified Access Gateway
- VMware vCenter Server 5.5
- VMware vRealize Log Insight
- VMware vRealize Network Insight
- VMware vRealize Operations
- VMware vRealize Orchestrator
- VMware vSphere Replication
- VMware Workspace Portal
Vmware Player 16 Could Not Find Component On Update Server
Performance issue:
Vmware Player Could Not Find Component On Update Server Settings
VMware is closely working with performance team to evaluate the patch testing to check performance costs of the Meltdown/Spectre mitigation for vSphere. Please check this VMware KB article on regular basis to know more on this.